(817) 447-7141
    Warehouse LED high-bay lighting retrofit cost in Dallas Fort Worth
    Back to Blog
    CommercialJuly 13, 20267 min read

    Warehouse LED Lighting Retrofit Cost in DFW (2026)

    Warehouse LED retrofits in DFW pay themselves back in 2–4 years thanks to Oncor commercial rebates and the collapse in LED fixture pricing. Here's the real 2026 scope and math.

    DFW warehouse with new LED high-bay lighting
    DFW warehouse with new LED high-bay lighting

    Real 2026 DFW Retrofit Pricing

    | Warehouse Size | Fixture Count (typical) | Installed Cost |

    |---|---|---|

    | 5,000 sq ft | 15–25 high-bays | $9,500 – $16,500 |

    | 10,000 sq ft | 30–50 high-bays | $18,000 – $32,000 |

    | 25,000 sq ft | 75–125 high-bays | $42,000 – $75,000 |

    | 50,000 sq ft | 150–250 high-bays | $82,000 – $145,000 |

    | 100,000 sq ft | 300+ high-bays | quote by design |

    Includes: UL-listed LED high-bays (150W–240W DLC-listed), photocell/motion sensors, disposal of old fixtures + ballasts, permit, and warranty registration.

    Oncor Commercial Rebates You Actually Get

    Oncor's Standard Offer Program (SOP) pays $0.09–$0.14 per kWh saved in the first year, capped at 50% of project cost. On a typical 25,000 sq ft warehouse:

  1. Old: 100 × 400W metal halide = 40 kW × 3,000 hrs/yr = 120,000 kWh
  2. New: 100 × 150W LED = 15 kW × 3,000 hrs/yr = 45,000 kWh
  3. Savings: 75,000 kWh/yr → ~$6,750–$10,500 Oncor rebate
  4. Plus $9,000–$12,000/yr in ongoing energy savings
  5. We handle the SOP paperwork — no upfront fee, rebate deducted from your invoice or paid direct to you.

    Old metal halide vs new LED high-bay side by side
    Old metal halide vs new LED high-bay side by side

    Payback Math (Real Client, Grand Prairie 30,000 sq ft)

  6. Project cost after rebate: $34,500
  7. Annual energy savings: $11,800
  8. Annual maintenance savings (no more ballast replacements): $2,400
  9. Simple payback: 2.4 years
  10. 10-year net savings: $107,500
  11. What's Actually Involved

  12. Photometric design — we lay out fixture positions to hit target foot-candles (30 fc for general storage, 50 fc for pick zones)
  13. Circuit assessment — LEDs draw ~⅓ the amps, but existing circuits still need verification
  14. Sensor strategy — motion + daylight harvesting adds 15–30% more savings for aisles that aren't always occupied
  15. Removal & disposal — old ballasts contain PCBs (pre-1979) or mercury; we handle certified disposal
  16. Install — typically 1 day per 5,000 sq ft with a 2-person crew and lift
  17. Rebate submission — we file the SOP application within 30 days
  18. What Makes a Warehouse Retrofit Go Sideways

  19. Cheap non-DLC fixtures — disqualify from rebate, fail in 2–3 years
  20. No photometric layout — dark corners or over-lit aisles
  21. Ignoring emergency egress lighting code
  22. Using screw-in LED bulbs in HID fixtures — code violation and warranty void
  23. Free On-Site Assessment

    We'll do a free photometric survey, model your energy savings against your real Oncor bill, and give you a fixed bid with the rebate net'd out. Call (817) 447-7141 or [request a commercial lighting quote](/get-a-quote).

    Need Electrical Help?

    Spillers Electric serves Burleson, Fort Worth, and the entire DFW metroplex. Licensed Master Electrician — fully bonded & insured.

    Commercial Electrical Near You

    Spillers Electric serves homes and businesses across the DFW metroplex.