    Bathroom Electrical Remodel Cost in DFW: GFCI, Exhaust Fans & Vanity Circuits

    Bathrooms are the most code-sensitive room in your house. Every outlet needs GFCI, every fixture over a tub or shower needs a wet-location rating, and every bath needs mechanical ventilation. Skipping any of it will fail inspection.

    Required Circuits & Fixtures

  1. 1× 20-amp GFCI circuit for all receptacles (one bath or multiple, as long as it only serves bathroom outlets)
  2. Separate lighting circuit (usually shared with adjacent hallway)
  3. Exhaust fan ducted to exterior (attic dumps fail Texas code)
  4. Wet-rated fixtures in shower area, damp-rated over tub
  5. Bathroom GFCI outlet and vanity lighting installation
    Bathroom GFCI outlet and vanity lighting installation

    Real DFW Bathroom Electrical Pricing (2026)

    | Scope | Typical Cost |

    | --- | --- |

    | Add GFCI + swap outlets (existing wire) | $220 – $450 |

    | New dedicated 20-amp bath circuit | $650 – $1,100 |

    | Exhaust fan install (new duct to exterior) | $475 – $850 |

    | Full bath remodel electrical (circuit, fan, vanity, sconces, shower light) | $1,800 – $3,200 |

    | Primary bath (heated floor, mirror TV, LED sconces, chandelier) | $3,500 – $6,500 |

    Common Bathroom Code Fails in Burleson & Fort Worth

  6. Fan ducted into the attic — must exit through soffit or roof
  7. 2. Non-GFCI outlets within 6' of sink

    3. Recessed light over tub without wet-location rating

    4. Switch reachable from tub/shower (must be 3' minimum from tub edge)

  8. No dedicated bath circuit — sharing with bedrooms triggers AFCI issues
  9. Bathroom exhaust fan properly vented through roof
    Bathroom exhaust fan properly vented through roof

    Heated Floors & Smart Mirrors

    These need their own dedicated circuits:

  10. Heated tile floor: 20-amp GFCI, mat wattage matters (0.5–1.5 kW typical)
  11. Smart mirror w/ defog: 15-amp circuit, often shared with vanity lighting
  12. Timeline

  13. Simple GFCI swap: 45 min – 1 hr
  14. New circuit + fan: 3–5 hrs (attic access dependent)
  15. Full remodel electrical: 2–3 days rough + 1 day trim, spread across the remodel
  16. Get a Fixed Bid

    We spec every bath in writing — fan CFM, fixture ratings, exact circuit counts — so there are no surprises at inspection. Call (817) 447-7141 or [request a bathroom quote](/get-a-quote).